SQL SEVER 安装出错:Error Code: 0x80070643 (1603)
admin
2023-06-07 08:41:23
0

安装SQL SERVER 2005时出现如下错误提示:

SQL SEVER 安装出错:Error Code: 0x80070643 (1603)

SQL SEVER 安装出错:Error Code: 0x80070643 (1603)

SQL SEVER 安装出错:Error Code: 0x80070643 (1603)

在以上提示的目录下找到文件:SQLSetup0005_K3_Core.log和SQLSetup0005_K3_Datastore.xml,打开第一个文件内容如下:

Microsoft SQL Server 2005 Setup beginning at Sat Aug 13 10:09:37 2016

Process ID      : 2252

D:\tools\SQL.2005.all.chs\SQL Server x86\Servers\setup.exe Version: 2005.90.1399.0

Running: LoadResourcesAction at: 2016/7/13 10:9:37

Complete: LoadResourcesAction at: 2016/7/13 10:9:37, returned true

Running: ParseBootstrapOptionsAction at: 2016/7/13 10:9:37

Loaded DLL:D:\tools\SQL.2005.all.chs\SQL Server x86\Servers\xmlrw.dll Version:2.0.3604.0

Complete: ParseBootstrapOptionsAction at: 2016/7/13 10:9:37, returned true

Running: ValidateWinNTAction at: 2016/7/13 10:9:37

Complete: ValidateWinNTAction at: 2016/7/13 10:9:37, returned true

Running: ValidateMinOSAction at: 2016/7/13 10:9:37

Complete: ValidateMinOSAction at: 2016/7/13 10:9:37, returned true

Running: PerformSCCAction at: 2016/7/13 10:9:37

Complete: PerformSCCAction at: 2016/7/13 10:9:37, returned true

Running: ActivateLoggingAction at: 2016/7/13 10:9:37

Complete: ActivateLoggingAction at: 2016/7/13 10:9:37, returned true

Delay load of action "DetectPatchedBootstrapAction" returned nothing. No action will occur as a result.

Action "LaunchPatchedBootstrapAction" will be skipped due to the following restrictions: 

Condition "EventCondition: __STP_LaunchPatchedBootstrap__2252" returned false.

Running: PerformSCCAction2 at: 2016/7/13 10:9:37

Loaded DLL:C:\WINDOWS\system32\msi.dll Version:3.1.4000.4042

Loaded DLL:C:\WINDOWS\system32\msi.dll Version:3.1.4000.4042

Complete: PerformSCCAction2 at: 2016/7/13 10:9:37, returned true

Running: PerformDotNetCheck at: 2016/7/13 10:9:38

Complete: PerformDotNetCheck at: 2016/7/13 10:9:38, returned true

Running: ComponentUpdateAction at: 2016/7/13 10:9:38

Error: Action "ComponentUpdateAction" threw an exception during execution.  Error information reported during run:

Error: Cannot read license file

Component update returned a fatal error : 1603

        Error Code: 0x80070643 (1603)

Windows Error Text: 安装时发生严重错误


  Source File Name: setup\sqlsetupactions.cpp

Compiler Timestamp: Thu Sep  1 22:23:04 2005

     Function Name: sqls::ComponentUpdateAction::perform

Source Line Number: 1564


Class not registered.

Running: UploadDrWatsonLogAction at: 2016/7/13 10:9:40

Message pump returning: 1603


解决方法:

        百度查出来的都是改注册表、改安装文件目录的方法,第一个修改后没用,第二个真不靠谱。分析自己操作的来龙去脉,重启服务器没用,查看文件夹内容,突然想起会不会被杀软误杀了什么东西导致(趋势杀软真不管用,还起反作用,垃圾。),幸亏还有一个ISO文件,比较了一下,不比不知道,一比吓一跳,复制到服务器上的解压后的文件夹才300+个,而原ISO文件有600+文件!原来是缺少文件导致的错误!赶紧重新复制ISO到服务器,用虚拟光驱打开,找到Server文件夹下的Setup文件运行,一切正常!

结论:

        遇到问题,首先还是要从最简单的原因和最简单的方法开始!

相关内容

热门资讯

AI热潮下的公关困境:英国企业... IT之家 5 月 24 日消息,据《卫报》今天报道,各大公关企业表示,英国各大公司如今正在想方设法把...
原创 6... 最近手机圈可太热闹了,小米、iQOO、红米、联想一个接一个地发新机,后面还有一大堆在路上,简直就跟下...
伊朗方面披露美伊或将签署的备忘... △伊朗德黑兰(资料图)总台记者24日自伊朗多个消息渠道了解到伊朗与美国或将签署的备忘录草案的部分内容...
京东工业发布AI智采管家 助力... 当前,新一轮科技革命与产业变革加速演进,人工智能正成为推动中国工业转型升级的核心引擎。长期以来,中小...
2026三门峡横渡母亲河活动启... 5月24日,2026年“大江大河”全国群众公开水域游泳系列赛(三门峡站)暨2026中国·三门峡横渡母...
led吸顶灯一半亮一半不亮怎么... 当 LED 吸顶灯一半亮一半不亮时,可能是以下原因导致的:1. LED 灯珠损坏:部分 LED 灯珠...
不让孩子看电视的方法 孩子们在成长过程中,电视是他们的一种娱乐方式,但是看电视时间过长会对孩子的健康和发展产生**影响。所...
奥克斯全自动洗衣自动进水管进水... 1、可能是水位开关性能不良,不能精准的识别水位,引起进水太多导致的。2、可能是溢水管本身损坏造成的。...
全自动洗衣机水管加长方法 对于家庭使用的全自动洗衣机来说,水管长度是需要考虑的重要问题。如果水管长度不够,就会给使用带来很多麻...
全自动洗衣机排水管怎么安装方法 波轮洗衣机排水管的更换方法:1、更换排水管前需要先准备一款新的排水管,更换排水管前不要忘记断开洗衣机...