ORA-12170: TNS:Connect timeout occurred ORA-06512: at "SYS.DBMS_SNAPSHOT"
admin
2023-05-15 00:21:54
0
Oracle job 无法自动运行 报以下大量的错

Errors in file /oracle/admin/orcl/bdump/orcl_j000_2158798.trc:
ORA-12012: error on auto execute of job 482
ORA-12008: error in materialized view refresh path
ORA-12170: TNS:Connect timeout occurred
ORA-06512: at "SYS.DBMS_SNAPSHOT", line 1883
ORA-06512: at "SYS.DBMS_SNAPSHOT", line 2089
ORA-06512: at "SYS.DBMS_IREFRESH", line 683
ORA-06512: at "SYS.DBMS_REFRESH", line 195
ORA-06512: at line 1
Sat Apr 26 21:57:53 2014
Errors in file /oracle/admin/orcl/bdump/orcl_j000_2158798.trc:
ORA-12012: error on auto execute of job 425
ORA-12170: TNS:Connect timeout occurred
ORA-06512: at "SYS.DBMS_SNAPSHOT", line 1883
ORA-06512: at "SYS.DBMS_SNAPSHOT", line 2089
ORA-06512: at "SYS.DBMS_IREFRESH", line 683
ORA-06512: at "SYS.DBMS_REFRESH", line 195


主要环境介绍,两个数据库之间要刷新物化视图,平时都是正常的,某天开始主库的自动job执行失败,而且是持续的失败

查看原因主要是ORA-12170: TNS:Connect timeout occurred TNS超时所致,排查思路大概可以定在网络上


1.网络排查

在两台主机之间互相ping各自的IP地址和网关,看有无丢包情况

期初查看经查看无丢包

2.查看防火墙1521端口是否正常

网络工程师确认防火墙1521端口正常开放,telnet 1521也是通的

3.tnsping 各自的服务名
$tnsping orcl
TNS Ping Utility for 64-bit Aix: Version 10.2.0.4.0 - Production on 05-6月 -2014 11:47:24
Copyright (c) 1997, 2006, Oracle Corporation.  All rights reserved.
Attempting to contact (DESCRIPTION= (ADDRESS_LIST = (ADDRESS=(PROTOCOL=TCP)(HOST =192.168.10.8)(PORT = 1521))) (CONNECT_DATA= (SERVICE_NAME=orcl)))
OK (0 msec)
OK (10 msec)


$tnsping yyzf
TNS Ping Utility for 64-bit Aix: Version 10.2.0.4.0 - Production on 05-6月 -2014 11:48:24
Copyright (c) 1997, 2006, Oracle Corporation.  All rights reserved.
Attempting to contact (DESCRIPTION= (ADDRESS_LIST = (ADDRESS=(PROTOCOL=TCP)(HOST =192.168.11.9)(PORT = 1521))) (CONNECT_DATA= (SERVICE_NAME=yyzf)))
OK (0 msec)
OK (10 msec)

tnsping服务名也是OK的

4.到此为止所有网络看似都正常,网络似乎应该不存在问题,但job还是一直是报错,由于两台主机不再同一个网段,ping任务在持续,忽然在某几个时刻有丢包现象,telnet 1521端口也存在某几次不通的现象这么看来网络还是有问题,最后跟客户确认说是有人重新规划过网络,于是查看主机ip和路由


Command: OK            stdout: yes           stderr: no

Before command completion, additional instructions may appear below.

Routing tables
Destination        Gateway           Flags   Refs     Use  If   Exp  Groups

Route tree for Protocol Family 2 (Internet):
default            192.168.10.1      UG       60 442255197 en0      -      -   =>
default            192.168.10.254    UG       40 432853407 en0      -      -
10.0.0.0           10.0.0.1          UHSb      0         0 en1      -      -   =>
10/27              10.0.0.1          U         1  11339108 en1      -      -
10.0.0.1           127.0.0.1         UGHS      0   1840821 lo0      -      -
10.0.0.31          10.0.0.1          UHSb      0        10 en1      -      -
10.0.1.0           10.0.1.1          UHSb      0         0 en0      -      -   =>
10.0.1/27          10.0.1.1          U         2  12382572 en0      -      -
10.0.1.1           127.0.0.1         UGHS      2   3268795 lo0      -      -
10.0.1.31          10.0.1.1          UHSb      0        10 en0      -      -
127/8              127.0.0.1         U        31   6493884 lo0      -      -
192.168.10.0       192.168.10.9      UHSb      0         0 en0      -      -   =>
192.168.10.0       192.168.10.10     UHSb      0         0 en1      -      -   =>
192.168.10/27      192.168.10.9      U         0    193565 en0      -      -   =>
192.168.10/27      192.168.10.10     U         1    209927 en1      -      -
192.168.10.9       127.0.0.1         UGHS     23  13738093 lo0      -      -
192.168.10.10      127.0.0.1         UGHS      0    151330 lo0      -      -
192.168.10.31      192.168.10.9      UHSb      0         0 en0      -      -   =>
192.168.10.31      192.168.10.10     UHSb      0         0 en1      -      -

Route tree for Protocol Family 24 (Internet v6):
::1                ::1               UH        0         0 lo0      -      -
  
  
  这样看来,主机的路由还是存在问题的,主机存在两条默认路由
  
  在AIX中如果有默认网关设置多个的话,会存在时断时续的丢包现象,于是进入AIX的路由表查看,果然存在两条默认路由,192.168.10.1和192.168.10.254,同一个网卡存在这样两条路由肯定是有问题的,两条路由的use使用都很高,与网络工程师确认后.254的路由是无效的,存在的原因可能是在之前修改路由的时候忘记***旧的路由导致



于是***废弃的路由

>#route delete  -if en0 default  192.168.10.254
192.168.10.254 net default: gateway 192.168.10.254

***路由后,观察一小时,所有job均执行正常,没有再出现TNS超时现象

看来,修改生产系统的任何参数都要按照严格的标准和检查流程才行,稳定重于一切


相关内容

热门资讯

“前半生是恶霸,后半生是学霸”... 一个人的逆袭叫传奇。一群人的集体转行,叫世道变了。文|张雪莹出品|Vista天下知识局提到日本黑帮,...
若不想成7年来第五个被赶下台的... 【文/观察者网 张菁娟】“这是自2022年保守党前首相特拉斯上任仅数周便仓促辞职以来,英国政局最动荡...
产学研各界代表齐聚一堂,共议A... 封面新闻记者 易弋力 20支战队4小时巅峰对决;三位大咖三个不同视角解读“技术打法+产业路径+数据洞...
评论丨香蕉复仇、蓝莓出轨?警惕... AI技术降低了创作门槛,不等于降低了质量门槛和责任门槛;可以利用AI“手搓”短剧,但不应没下限地制造...
人工智能如何重塑电影行业?中国... 北京5月15日电 (记者 孙自法)人工智能生成内容(AIGC)正为众多行业带来深刻巨变,引发广泛关注...
济南隆超取得便捷式喷涂装置专利... 国家知识产权局信息显示,济南隆超石油机械锻造有限公司取得一项名为“一种便捷式喷涂装置”的专利,授权公...
原创 国... ## 国际空间站宇航员在微重力环境下与新鲜水果合影 维生素C很重要,即使在太空中也是如此。 来源:...
原创 低... 手机厂商的618活动陆续都开启了,在苹果宣布iPhone 17 Pro系列降价千元后,华为也迅速跟进...
微信第一行代码曝光! IT之家 5 月 15 日消息,据 CCF 计算机博物馆官方消息,2026 年 5 月 15 日,中...
光鼎电子取得LED数码管灌胶设... 国家知识产权局信息显示,连云港光鼎电子有限公司取得一项名为“一种LED数码管灌胶设备”的专利,授权公...