数据库中出现RMAN-06820 ORA-17629错误怎么办
admin
2023-05-09 11:22:00
0次

在standby数据库进行数据库备份,如下:

oracle@node1:~> rman target /

Recovery Manager: Release 11.2.0.4.0 - Production on Thu Jun 4 06:45:04 2015

Copyright (c) 1982, 2011, Oracle and/or its affiliates.  All rights reserved.

connected to target database: ORACLE (DBID=1753883584, not open)

RMAN> backup database format '/home/oracle/fulldb_%U.bak' plus archivelog format '/home/oracle/arch_%U.bak' delete all input;

Starting backup at 04-JUN-15

using target database control file instead of recovery catalog

RMAN-06820: WARNING: failed to archive current log at primary database

ORACLE error from target database: 

ORA-17629: Cannot connect to the remote database server

ORA-17627: ORA-01017: invalid username/password; logon denied

ORA-17629: Cannot connect to the remote database server

在standby数据库执行数据库备份报如上红色字体错误,官方给予处理方法如下(经测试,主备库应设置相同的密码,否则同样存在问题)

数据库中出现RMAN-06820 ORA-17629错误怎么办RMAN-06820 ORA-17629 During Backup at Standby Site (文档 ID 1616074.1)

数据库中出现RMAN-06820 ORA-17629错误怎么办

In this Document

SymptomsChangesCauseSolutionReferences


APPLIES TO:

Oracle Database - Enterprise Edition - Version 11.2.0.4 and later
Information in this document applies to any platform.

SYMPTOMS

RMAN archivelog backup at the standby site is throws the following errors at the start of the job:


Starting backup at 15-JAN-2014 13:44:46
RMAN-06820: WARNING: failed to archive current log at primary database
ORACLE error from target database:
ORA-17629: Cannot connect to the remote database server
ORA-17627: ORA-01017: invalid username/password; logon denied 
ORA-17629: Cannot connect to the remote database server

 

But the rest of the backup actually complete successfully:

 

skipping archived log of thread 1 with sequence 607; already backed up
skipping archived log of thread 1 with sequence 614; already backed up
channel t1: starting archived log backup set
channel t1: specifying archived log(s) in backup set
input archived log thread=1 sequence=678 RECID=290 STAMP=836919086
input archived log thread=1 sequence=679 RECID=291 STAMP=836919369
input archived log thread=1 sequence=680 RECID=292 STAMP=836919706
input archived log thread=1 sequence=681 RECID=293 STAMP=836919873
channel t1: starting piece 1 at 15-JAN-2014 13:44:52
channel t1: finished piece 1 at 15-JAN-2014 13:46:17
piece handle=LOG_THMDB_20140115_171228_1_1 tag=LOG_TWMDB comment=API Version 2.0,MMS Version 5.4.1.0
channel t1: backup set complete, elapsed time: 00:01:25
Finished backup at 15-JAN-2014 13:46:17

 

 

CHANGES

 Database was upgraded to 11.2.0.4

CAUSE

Per 'unpublished' Bug 8740124, as of 11.2.0.4, we now include the current standby redo log as part of an RMAN archivelog backup at the standby site. This is achieved by forcing a log switch at the primary site.

However, the connection to the primary failed when attempting to do so.


This is due to this bug:
      Bug 17580082 - ACTIVE STANDBY - RMAN-06820: WARNING: FAILED TO ARCHIVE CURRENT LOG AT PRIMARY
 

SOLUTION

Workaround

Do not use operating system authentication to login with RMAN. Use a username and password.

That is, do not use just the "/" (operating system authentication) connect to the standby database:

$ rman target /


Instead put in the username and password for the SYSDBA user:


$ rman sys/password

 


 

REFERENCES

BUG:17580082 - ACTIVE STANDBY - RMAN-06820: WARNING: FAILED TO ARCHIVE CURRENT LOG AT PRIMARY

NOTE:8740124.8 - Bug 8740124 - Current standby redo log group should be included in the database backup by RMAN
NOTE:1301769.1 - ORA-17629 : RMAN Resync Catalog from db_unique_name all fails

相关内容

热门资讯

空调连续工作多久需要停机休息 空调连续工作的时间取决于多个因素,包括空调的型号、功率、使用环境和维护情况等。一般来说,空调可以连续...
空调哪个符号是除湿的 空调除湿功能通常用一个水滴形状的符号表示。不同品牌和型号的空调遥控器可能会有所差异,但一般来说,除湿...
格力空调多长时间加一次氟利昂 1、一般情况下,空调对氟利昂的使用量是非常小的,所以在空调使用了四年左右的时候再考虑加也没问题。2、...
空调用多长时间需要加氟一次 一般情况下是五年。当出现以下这几种情况时,空调才需要加氟。1、空调的室内机和室外机各有两个接口,当接...
格调生活·C标思享荟:卡萨帝在... 9月12日的郑州龙湖金融岛,夜风轻拂,灯光璀璨。“C标时刻共传奇——卡萨帝思享荟暨20周年品牌盛典郑...
品牌价值破千亿、高端份额持续领... 9月12日,“C标时刻共传奇——卡萨帝思享荟暨20周年品牌盛典郑州站”在郑州龙湖金融岛举办。2026...
空调主板坏了修800还是换新的 空调主板坏了是修还是换新,需要考虑多个因素,以下是一些建议:1. 维修成本:如果维修费用较低,比如 ...
空调开多久需要休息多长时间 问题:空调开多久需要休息多长时间回答:1、在使用空调的过程中,一般空调开7~8个小时左右需要休息2~...
中央空调多长时间清洗一次 1、一般空调开机前清洗一次即可,空调开机中间时段再清洗一次,空调关机时清洗一次,这样比较合理。2、空...
中央空调氟利昂多久加一次 看空调制热和制冷程度,很多人的观点认为氟利昂必须一年放一次,其实这个观点是错误的,理解上面有点偏差,...