数据泵导出出现ORA-31617错误
admin
2023-05-02 19:04:13
0

Export: Release 11.2.0.4.0 - Production on Sat Jun 11 01:00:02 2016


Copyright (c) 1982, 2011, Oracle and/or its affiliates.  All rights reserved.

;;; 

Connected to: Oracle Database 11g Enterprise Edition Release 11.2.0.4.0 - 64bit Production

With the Partitioning, Real Application Clusters, Automatic Storage Management, OLAP,

Data Mining and Real Application Testing options

Starting "SYS"."SYS_EXPORT_SCHEMA_04":  "/******** AS SYSDBA" directory=bak_dump dumpfile=exp_unspaydb_20160611.dmp logfil

e=exp_unspaydb_20160611.log schemas=vnv parallel=6 

Estimate in progress using BLOCKS method...

Processing object type SCHEMA_EXPORT/TABLE/TABLE_DATA

Total estimation using BLOCKS method: 21.77 GB

Processing object type SCHEMA_EXPORT/USER

. . exported "VNV"."TRANSACTION_HIS"                     2.949 GB 10892506 rows

Processing object type SCHEMA_EXPORT/SYSTEM_GRANT

Processing object type SCHEMA_EXPORT/ROLE_GRANT

Processing object type SCHEMA_EXPORT/DEFAULT_ROLE

Processing object type SCHEMA_EXPORT/PRE_SCHEMA/PROCACT_SCHEMA

Processing object type SCHEMA_EXPORT/SYNONYM/SYNONYM

Processing object type SCHEMA_EXPORT/SEQUENCE/SEQUENCE

Processing object type SCHEMA_EXPORT/TABLE/TABLE

Processing object type SCHEMA_EXPORT/TABLE/GRANT/OWNER_GRANT/OBJECT_GRANT

Processing object type SCHEMA_EXPORT/TABLE/COMMENT

Processing object type SCHEMA_EXPORT/FUNCTION/FUNCTION

Processing object type SCHEMA_EXPORT/PROCEDURE/PROCEDURE

Processing object type SCHEMA_EXPORT/FUNCTION/ALTER_FUNCTION

Processing object type SCHEMA_EXPORT/PROCEDURE/ALTER_PROCEDURE

Processing object type SCHEMA_EXPORT/TABLE/INDEX/INDEX

Processing object type SCHEMA_EXPORT/TABLE/INDEX/FUNCTIONAL_INDEX/INDEX

Processing object type SCHEMA_EXPORT/TABLE/CONSTRAINT/CONSTRAINT

Processing object type SCHEMA_EXPORT/TABLE/INDEX/STATISTICS/INDEX_STATISTICS

Processing object type SCHEMA_EXPORT/TABLE/INDEX/STATISTICS/FUNCTIONAL_INDEX/INDEX_STATISTICS

Processing object type SCHEMA_EXPORT/TABLE/CONSTRAINT/REF_CONSTRAINT

Processing object type SCHEMA_EXPORT/TABLE/STATISTICS/TABLE_STATISTICS

. . exported "VNV"."TRANSACTION"                         2.193 GB 5947080 rows

. . exported "VNV"."T_BANK_TRANS_DC_HIS"                 1.938 GB 1316266 rows

ORA-31693: Table data object "VNV"."TRANSACTION_BAK_0518" failed to load/unload and is being skipped due to error:

ORA-31617: unable to open dump file "/data/orabackup/exp/exp_unspaydb_20160611.dmp" for write

ORA-19505: failed to identify file "/data/orabackup/exp/exp_unspaydb_20160611.dmp"

ORA-27037: unable to obtain file status

Linux-x86_64 Error: 2: No such file or directory

Additional information: 3

ORA-31693: Table data object "VNV"."ID_CARD_INFO" failed to load/unload and is being skipped due to error:

ORA-31617: unable to open dump file "/data/orabackup/exp/exp_unspaydb_20160611.dmp" for write

ORA-19505: failed to identify file "/data/orabackup/exp/exp_unspaydb_20160611.dmp"

ORA-27037: unable to obtain file status

Linux-x86_64 Error: 2: No such file or directory

Additional information: 3


数据泵的并行度设置为10,同时向10个DUMPFILE中写入数据。在写入时出现ORA-31693、ORA-29913和ORA-31617错误。

发现对于RAC环境而言,Oracle会尝试将并行导出放到两个节点上,而由于DIRECTORY是本地磁盘,且在另外一个节点上没有建立同样的目录,因此打开文件报错的信息。

那么如果想要使用RAC上的并行导出,确保相同的目录在两个节点上同时存在。如果只想在一个节点上执行数据泵的导出那么就不要使用并行方式。


相关内容

热门资讯

冰箱漏电怎么测 1、可以用灯泡检查法来检测冰箱漏电,将36V灯泡的两根导线,一根接冰箱外壳(无漆处)另一根接大地,如...
电饭煲通电就跳闸怎么回事 如果之前电饭煲从未出现过跳闸现象,此现象为新出现的,有可能是插板或者是电饭煲发生故障导致的。首先可以...
空调外机有温度传感器损坏 最可能是温度传感器泄漏导致的这个原因。可以使用热毛巾加热温度检测管,将按钮设置为最低温度,并使用测试...
九阳铁釜电饭煲故障代码种类及解... 故障代码的种类很多,有E0表示电饭煲上盖热敏电阻故障,需要更换上盖的热门电阻;E1是热敏电阻故障,需...
九阳电饭锅的拆卸步骤 先拆锅底的四个小螺丝,然后将暴露出来的底拆开,然后拆卸电饭锅那儿的小盖板,用螺丝刀拆螺丝就行,然后将...
华南理工男生课堂偷拍女生被当场... 据羊城晚报消息,5月13日,一段“华南理工大学男生教室偷拍女生”视频在网络传播,相关事件引发热议。视...
偷税超900万被查的网红白冰:... 刚刚,因偷税超900万元被查的网红白冰发布近60分钟长视频,控诉前员工联合他人侵吞公司资金、设局陷害...
AI人才需求攀升,如何打开就业... 当前正值高校毕业生求职关键期。记者在劳动力市场看到,随着人工智能蓬勃发展,各行业各领域对AI(人工智...
5月14日、15日土星火星上演... 5月14日、15日土星火星上演合月“接力赛” 5月14日、15日日出前,东方低空将接连上演土星合月...
投身具身智能,它石丁文超:知行... 90后、“天才少年”、博导...它石智航首席科学家丁文超身上有不少标签。他曾参与主导真正意义上的第一...